why we use to transmit the power in three phases intead of
single phase ?
Answer Posted / bala
l.power generation is 3 phase. so power transmission also
in 3 phase.
2.Quantity of power transmission also consider in case of 3
phase we can transmit more power than conpare to single
phase.
| Is This Answer Correct ? | 4 Yes | 7 No |
Post New Answer View All Answers
What is the function of a neutral reactor.
i have a 1500kVA transformer what is the kWH meter i need to use?
Installation method of self treated earth electrode.
dg earth connect only in the amf panel or not why
what is the function of Moulded case circuit breaker, why it is called Moulded?
What is CVT and what is relation with wave trap?
1) why a dg set shows variation of power factor and load when synchronised with other dgs? 2)Why the load sharing is not become equal in all dgs?. 3)When a dg set will not run on auto start?
A Question Like A Wire Is Wound Whose Resistance Is Some 132. 44647 Ohms. If A Voltage Of 30 mv, 296 Ma Current Is Applied To It What Is The Resistance.
lenz law application and define
What is a DC series motor?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
What are the major reasons for balancing hydro-thermal mix?
I have a small system with two motors that are running on 380 vac, 60 hz. These motors are expensive and I usally get them from Brazil. I am adding another motor to the system, but I want to purchase a 480 vac, 60 hz motor to use. It will be on a VFD that is rated fro 380 thru 480. Is this posible and will I have to use a larger motor and derate it?
WILL SCHNEIDER MAKE ACB(MASTERPACT)TRIP ON REVERSE POWER?