Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how to select a circuit breaker?

Answer Posted / sandipan gandhi

CB is selected on the basis of it's Breaking capacity,
Making capacity, operating voltage, operating
current,system frequency, insulation level & type of use
i.e indoor or outdoor.

Is This Answer Correct ?    24 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

define the active power?

2014


As per the Anchor capstan motor specification, full load current is 200A. starting current is 1750 A and acceleration time is less than 8 seconds. Please guide for selection of cable size.

1848


if we look on phasor of the transformer vaoltage is 180 oppsite at primary and the secondary so to improve a power factor is secondary should kept negative to improve it primary side means is -.90 became +.90 at other side

1856


How to measure size of cable on a given load

1831


What is meant by Im=30mA@Vk/2. How to know the kee point voltage for CT design

3452


hi friends ,iam working as genset AVR service engineer in electrical field from past 2 yrs throughout india . i plan to shift in some other job without travelling in same field because i con't travel,i dont know what i do for that so please guide me what job is suited for me,how i can serch the job please anybody helpme iam totally confused

2022


How we select the vector group of 3phase power transformer?

2729


why booster transformer is used in sumpners test conducted on transformer????

3578


How impulse levels are calculated that for 11kV impulse is 75kvp, for 24kV impulse is 125kvp ?

2000


How to calculate VCB rating for 33KV ,25 MW Power line?

1748


In PFI plant one stage capacitor connection is directly connected(with out megnetic contact controll). but why?

2289


Why is the frequency not changed during transformation of electrical energy in a transformer?

1403


what is the safety of voltage power transformer(2250KVA0

1982


what is the difference between torque induced and torque load?compare them with respect to dc motor?

2303


how a flip flop can be used as a latch?

1992