Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why the voltage level is changed when the unearth cable is
earth

Answer Posted / z_hosen

When any 3-phase 4-wire system (Y/star) is not earthed
(neutral not earthed) then the system is not balanced and we
can't say what is the neutral current is? but when we
earthed neutral then it is a balanced and neutral current
almost zero.as a result voltage level is changed when the
unearthed cable is earthed.

Thanking u
z_hosen@yahoo.com

Is This Answer Correct ?    9 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why can we use cosine wave instead of sine in ac supply as both have same rms vale and ripple factor

2537


please give some hindalco placement papers for written exam

1793


how to test and calculat the head and discharge in borewell compressor

2145


what is earth pit , how we can measured it, what earth rods reference

2583


How may I get the maximum current capacity for a particullar size Alluminum or Copper cable if there is compulsion to use?

1888


stand by earth fault protection (51G) for transformer rating 2000 kVA,Dyn11,33/0.400 V. LV NCT ratio and necessary resistor and metrosil values how to calculate

2780


How to work definite,over pluxing,revers power,OSR relay

1766


what is differnce btwen lll and lllg faults

1990


Why are the laminations insulated from each other?

1139


WHat is the general checks required for Dry type transformers

2065


why we use circuit breakers for switching instead of normal switching device?

1858


11kv/433v delta/star distribution transformer primary side full load Ht current is 83.33A in , but input side VCB rating 800A.why?

1649


sir, i'm preparing for hpcl exam officer trainee pls tell me how the exam ques paper pls pls

2233


how to choose cable size with respect to load? how to convert cable size in mm2 to sq.mm?

5955


What are the advantages of instrument transformer?

1139