Why size of HT cable is less then LT cable inspite of the
fact that voltage is higher in HT cable?
Answer Posted / rainy
Hirer the voltage the lower the current. And the lower the
voltage the lower the current. Say for instance if you were
feeding the high side of a transformer with 230kv and the
sec. side was 100kv usually the size of conductors would be
(high side 1 mill. and on the low side would be 2 mill.
wire size usually dual conductors to carry the load on the
low side.
| Is This Answer Correct ? | 6 Yes | 14 No |
Post New Answer View All Answers
what is the function of bearing in dc mchine" and where it is placed
how to check three phase motor torque value?
What are the advantages of a three-phase system over a single-phase system?
Explain how you intend to work under pressure to meet up with deadline target?
distribution is maximum done by a)radial b)network c) parallel d)b & c
What is Icu and Ics and what is difference b/w them. please tell me how to calculate a size of a copper bar for a system or a breaker... reply on... king.arish@gmail.com would be waiting for a logical answer.
how we can find of current direction(supply comming/out going direction) when a transmission line passing through sides.
If o/p power is doubled by how much does the sound increase
what is Anti-pumping?
what is the meaning of the symbol << >> put in transformer drawing
hi friends if you have any 400KV Substation Erection and installations Drgs please send to me.My email id:kandi.suresh441@gmail.com
how to find the voltage's of a transmission line plzz help with pictures i am not able to understand
Why we make earth connection with Transformer Body and What will be the minimum size of copper wire as per code with respect to KVA rating of Transformer?
I have a current transformer with 1 main reading meter with transformer outside the building and a control panel having 5 CT reading meters with black round coils inside the building. I want to know, A) when current pass through the Transformers, will the current be reduced or be the same and after that B) when current pass through the CT meters with black round coils, will the current be reduced or be the same. C) in the above process will the reading of the main meter be same or different, from the total reading of all the 5 CT meters.
for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance