Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference between VARIAC,AUTO
TRANSFORMER,DIMMERSTAT.

Answer Posted / mahesh ch

all are same........tese are different names.

Is This Answer Correct ?    27 Yes 12 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

The inventer is a battery, but if lost current at home u will turn on the fan but the is AC and inventer battery is dc . Then how the fan was rotating. What device Or machine in fan converst the Dc power to Ac power

1229


What is the dc grounding system and what is diff between AC/DC grounding system?

2170


what is KA rating and how can we choose switchgears on applications

1503


how to select the no. of brushes in a lap winding?

2243


TO CALCULATE THE RESISTANCE OF GRR OF HT MOTOR 400KW WHEREAS STATOR VOLTAGE 6.6KV AND ROTOR VOLTAGE 705V AND ROTOR CURRENT IS 346A.

5566


What is resolution of a measurement?

1255


what are the factors to be considered while design the breaker either HT or LT??

1975


How to find out damper winding failure for synchronous machine?

1571


what is mathed of check the D.C MOTOR 181 KW (ARMATURE AND FIELD) WHAT IS THE MATHED OF CHECK THE THYRISTOR MODULE (HIGH CURRENT)

2088


Why and when NGR panel required. Is it necessary to design a NGR panel for a 6.6kV Alternator paralleling with Grid????

2810


Earth leakage relay basic knowledge principle

2240


in a solar power plant,we are going to step up the voltage 350V to 33kv, and to 132kv GSS. i want to ask that if it is possible that 315v/33kv is not possible because we also use 315v/11kv. or it should be 415v/33kv? is it effects generation or losses?  the second question is-generation is depends on LV winding? or LV winding design for generation voltage?

1786


Draw a SLD of DG distribution up to main LT panel?

9528


why the neutral line is not giving shock to us if we touch it ?

1842


What is the drawback of static coefficients?

1679