Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

State the difference between Surge Arrester and Lightning
arrester,Both are same or not?

Answer Posted / s bhattacharya

LIGHTNING ARRESTOR IS NOT SUPPOSED TO CONDUCT AT POWER
FREQUENCY.
WHEREAS SURGE ARRESTORS ARE SUPPOSED TO CONDUCT AT POWER
FREQUENCY.
THIS IS THE FUNDAMENTAL DIFFERENCE .

Is This Answer Correct ?    42 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Starting Time of LT & HT Motor

1985


Explain the construction of the conservator, operation and purpose, and draw the diagram of the conservator.

2554


how you configure motorvision relay (L&T make)from DCS

4961


what is the operating time for LBB and how does the LBB relay realise whether cb is opened or not?

2034


explain the mode of metal iranafer in Co,welding

1636


in star-delta tranformer,if the input of star connection is 400/7v 3 kva then what is the output of delta connection?

2181


how can we say that stator magnetic field rotates with synchronous speed?can we derive?

1818


Why earthing is necessary for any equipment?

1781


howmany electrician should maintain for a 1000 kva used plant... in kerala..

2156


how we calculate the dick for a pole?

2234


This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

2522


If i am running of spindle at 2000rpm ,but How to spindle stop at the second I am resetting the machine in CNC machines

1682


what is KSR type transmission tower? What is LSR type transmission tower?

5429


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2197


is that any software calculator to calculate the size of cable

2395