State the difference between Surge Arrester and Lightning
arrester,Both are same or not?
Answer Posted / s bhattacharya
LIGHTNING ARRESTOR IS NOT SUPPOSED TO CONDUCT AT POWER
FREQUENCY.
WHEREAS SURGE ARRESTORS ARE SUPPOSED TO CONDUCT AT POWER
FREQUENCY.
THIS IS THE FUNDAMENTAL DIFFERENCE .
| Is This Answer Correct ? | 42 Yes | 6 No |
Post New Answer View All Answers
Starting Time of LT & HT Motor
Explain the construction of the conservator, operation and purpose, and draw the diagram of the conservator.
how you configure motorvision relay (L&T make)from DCS
what is the operating time for LBB and how does the LBB relay realise whether cb is opened or not?
explain the mode of metal iranafer in Co,welding
in star-delta tranformer,if the input of star connection is 400/7v 3 kva then what is the output of delta connection?
how can we say that stator magnetic field rotates with synchronous speed?can we derive?
Why earthing is necessary for any equipment?
howmany electrician should maintain for a 1000 kva used plant... in kerala..
how we calculate the dick for a pole?
This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.
If i am running of spindle at 2000rpm ,but How to spindle stop at the second I am resetting the machine in CNC machines
what is KSR type transmission tower? What is LSR type transmission tower?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
is that any software calculator to calculate the size of cable