Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

If the supply voltage is same (say 440V) whether a system
designed for 60 Hz frequency will work with 50 Hz frequency
or not , if so pl. give clarification.

Answer Posted / joysbag@gmail.com

E=4.44(freq.)x(fluux density).

if E is constant - freq is inversly proportional to Flus
density.

Hence with 10% decrease in freq the flux density will
increase by 10% which may bring the transformer at
saturation. Hence it may work but not advisable.

Is This Answer Correct ?    11 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is meant by brushed alternator & its working principle ?

1974


why do we have spikes enough to burn electronic boards, when generators are not grounded

1861


Differentiate between digital phase converter and ordinary phase converter.

1281


Is there possible to Test Transformer for Overfluxing Capability. Or is there any firm who does Overfluxing Test on Transformer?

3173


how to compute kAIC?  with formulas...

4294


BRIEFLY EXPLAIN THE STORAGE CLASSES AND THEIR TYPES IN C

2392


Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.

2085


why the check zone and main zone are used for Busbar Protn. scheem?

2239


advantage and disadvantage of team work?

1749


how to calculate the battery AH

2812


What are unstable systems?

1168


detailed procedure how we calculate cost for pcc m10 and rcc m20 including centering and labour excluding steel/ iron

3175


what is the diff. between x'mer , isolation x'mer & ultra-isolation x'mer ?????????????

2411


what is the maximim current drawn by 1 phase and three phase welding machine

1915


how to apply b license to c license in tneb

1872