1.what is the contact resistace of CB ?
2.radioactivity should be mesured with---------?
Answer Posted / rabi
20 micro ohm. it may be less than 20 micro ohm.
| Is This Answer Correct ? | 16 Yes | 4 No |
Post New Answer View All Answers
A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram
1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?
How I calculate the ELCB for circuit breakers?
What is the safety of UPS?
Define active and passive network?
What is meant by analogous system?
please send privious years question papers of jindal steel and power ltd.My e mail id is rajanikant.sngh@gmail.com
Hi friends, i m electrical engineer i want a cdr for migration purpose so anybody have information about this then send me on jayesh_ee88@yahoo.com.please try to me
What happen if we apply square wave or traiangular waveform voltage to the transformer primary winding instead of sinusoidal wave?
for compensate 315mh inductance ,how many capaciance required?
What is the permissable nutral current of three phase system as per IS standards?
How we calculat the NGR of 3phase Generator, Our generation voltage 11KV
Did RMU have ct and pt ?
what material is used in capaciter
What is highest size of HT motor like 11 kv or 33 kv,and how to make it 750 rpm.i think the size will be very big.any idea ? pl. reply..