Comparative difference between 33Kv & 66KV for transmitting
the load of 7 MW at a distance of 34 Km.
Answer Posted / ayush
1.as voltage of line is increased current is decreased.so
the copper losses associated wth current r reduced.but iron
losses dependent on voltage r increased.as the supply
voltage is constant so r the iron losses.but copper losses
vary wth load(load current)bcz current is less we cn say
that overall losses i.e. cu nd iron losses r reduced.
2.as nw supply votlage is increased size of current
carrying conductor reduces as current is low so less area
required for power dissipation.
3.as losses r less so higher is the effiency of line so is
the power transmission capability.
| Is This Answer Correct ? | 12 Yes | 0 No |
Post New Answer View All Answers
Can you used moeller lzm1 mccb in a dc system with 125vdc and 20ka short circuit current , beside is it have 24 or 48 volt shunt ? Beside how long current can through from An MCB shunt contacts? (like Z7-AS 24 V)?
kindly send me 11KV MV motor differential protection procedure by primary injection method.
WHAT IS THE MEANING OF BALANCED / UNBALANCED IN STABILIZER TYPES.
Is there a standard depth of gravel fill in Substation Switchyard? Please give a design/drawing. Thank you.
I need bhel electrical test pattern & paper
how you will decide the distance between the power transformer and its fencing
What types of CMOS memories have you designed? What were their size? Speed? Configuration Process technology?
If not into production, how far did you follow the design and why did not you see it into production?
Why neutral point is consider as zero potential?
pls someone send me sample question papers along with the key.thanks in advance
xfhnchncv?
PLEASE ANYBODY HAVE ELECTRICAL CIRCUIT DIAGRAM FOR CHMER PULSE CD 60M SPARKING MACHINE.PLEASE MAIL ME SUPRIYAAYYAPPAN@YAHOO.CO.IN.
1- XC and the RC time constant are both measures of the reaction of C to a change in ____? 2-The power factor is a numerical ratio with a value between 0 and 1 equal to the ______________ of the phase angle. 3-When V and I are out of phase because of reactance, the product of V times I is called ______________ power 4-For _____________ inductors, the branch currents can be added algebraically. 5- The ______________ power in watts can be calculated as I^2R 6-Calculate XL with L = 30mH and f = 1kHz ( I have Xl=2piFL 2*3.141592653*1kHz*30mH =188 ohms Please check) 7-A parallel RL circuit has the values, R = 5kohms, XL = 5kohms. A voltage source of Vt = 10Vrms is connected in parallel to R and L. Determine the total current, It delivered by the voltage source Vt. 8-A series RC circuit has R = 1Mohm and C = 1microF. How long would it take for the capacitor to fully discharge if it is initially fully charged? 9-A circuit has real power = 300W and an apparent power of 500VA. Determine the power factor and phase angle. 10-The time constant for an LR series circuit is T = 0.1s and R = 10ohms. Calculate the inductance L.
please send the last 5 years {{{JUNIOR ENGINEER - ELECTICAL, ELECTRONICS RRB CHENNAI and secundrabad}}} TECHNICAL question papers TO MY EMAIL ID dinesh100701@gmail.com
can i able to get bhel previous exam question paper?