As we know,charged clouds(from which lightning stroke
initiates)may be charged with either +ve charge or -ve
charge.
Now say one cluster of cloude is fully charged with +ve
charge & another cluster is fully charged with -ve charge.
In the sky these two cluster of charged clouds have come in
such a distance that, if they come clouser by some few
yeards then the lightning discharge will take place between
these two cluster of clouds. Under such a situation an
Aircraft came inbetween. what happend??
Answer Posted / shinyvikram ganji
ACTUALLY THERE ARE MANY THEORIES REGARDING LIGHTNING STROKE.
EACH HAS ITS OWN WAY.
SOME THEORIES SPECIFES ABOUT THE GROUNDING CONDITION.SO
FOR A LIGHTNING STOKE GROUNG MUST BE COMPULSORY.OTHER WISE
THERE IS NO CLOSED PATH FOR THE LIGHTNING CURRENT.
SO WHENEVER PLANE COMES IN BETWEEN THERE IS NO GROUND,
HENCE PLANE WILL NOT BE AFFECTED.
| Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
which cable is used for 15 Hp monoblock pump 3phase and service wire Distance is 210 feet please tell me cable size Armaured
Why Transformer Neutral having one earth pit ( more earth electrode resistance) whereas body have many earth pit ( less earth electrode resistance)?
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
Who are the manufactures those manufacturing 3Cx2.5sqmm FRLS cables. I heard about FRLS technology adopted only in wires useful for wirings
pls tell me function of closing coil of A.C.B.
what is the minimum recommended leakage current of an earthed cable connected to the body or skid of an alternator
which pump used in STP
What is Phase to Phase clearance for 800V System Operating Voltage as per IEC61439
what questions will be asked for 11/33KV licence interview APSEB hyderabad. Can any one share question and answers.
How to calibrate or test an LT Air Circuit breaker 440 volts, 35 KA, 800 Amps ?
If 24 KVA AVR having Input voltage 200-400v, Output voltage 415+-1%, what will be the voltage if Load is 13A.
What are the classifications of oscillators?
How can we select suitable capacity generator for three phase load (inductive load) and how to take study analysis in 3 three phase load system ?
What is K-rated transformer? What is the use of it? What can be the size(pls provide calculation if possible) of K- factor transformer for 550kW,690V motor operating with drive (VFD)?
How grounding is different than earthings?