why do we generate sinusoidal ac?can we generate some other
waveforms by alternators?
Answer Posted / fonzy umali
ALTERNATOR CAN ONLY GENERATE SINE WAVE THAT IS..0 TO 180
THEN 180 TO 360 DEGREES. DERIVE FROM THE ROOT WORD
ALTERNATOR MEANS IT VARIES FROM POSITIVE TO NEGATIVE WAVE
OR VICE VERSA..IT MIGHT PRODUCE RIPPLE DURING WHICH STATICS
OR HARMONICS BUT IT ALWAYS HAVE POSITIVE AND NEGATIVE WAVE.
| Is This Answer Correct ? | 2 Yes | 3 No |
Post New Answer View All Answers
who can measure the size of power cable?
my name is venkat .i have good percentage in my academics(ssc 86, intermediate 83 b.tech 73) my question 1..after completion of my ssc i joined in bpc but i didnt got rank in emcet so i completed MPC in one year compartmentally ..so here what am expect question from this background?
what is the formula of starting current of 3phase and 1 phase motor???
WHAT SHOULD BE THE BEST CURRENT RATINGS (PRIMARY / SECONDARY)FOR A CT INSTALLED AT THE INCOMING 11KV PANE? WILL IT BE CALCULATED ON THE BASES OF MAXIMUM DEMANT VALUE OR ON SUM OF ALL TRANSFORMER'S KVA? NOMALLY MAX DEMAND REPRESENT THE MAXIMUM OPERATING LOAD OF THE PLANT AND TOTAL KVA OF (SAY 5 NUMBERS TRANSFORMERS) REPRESENT THE CONNECTED LOAD. WHICH i.e. MAX DEMAND KVA OR CONNECTED KVA ARE BETTER TO USE FOR CT CURRENT CALCULATION? PLEASE ANSWER.
What is the difference between rulling span and wind span of of an Over Head Transmission Line?
why we use four type of phase angle difference between pimary & secondry winding of a transformer & where we use them?
how to find three phase complex power in per unit and MVA?
Currently what is the highest capacity (MVA) of SPPg generator available in the market?
plz send me the procedure and syllabus for mseb exam
What is center gravity load in substation?
why it is not advisable to run low rating (19KVA) DG sets in parallel for long durations even though they are provided with droop ckts (QDC)
This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.
What is magneto on a gas generator. how it functions. its out put is d.c or a.c. how it can be checked for correct functioning
Which motor connection is preferable star-delta or delta-star?
what is inter connected dc generator?