Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how to reduce power loss when the tranmission under long
distance?

Answer Posted / comil83

To reduce power loss in HV line u have to reduce current in
trasmission line so voltage will remain as high as
pssible.so u can overcomes from more voltage dropp.For
reducing current in line u have to apply the formula R =
L/A.Where L leanth of conductor and A = circumfanc of
conductor.In ur case lenth of con. is long.so to reduce R u
have to increace A(Thick cable).If R is reduced then losses
of voltage will less but it will also increase your capital
cost of cable transmission.Other way is you can us step up
X'mer at some distance u can improve ur voltage trnsmission
but in this cas also capital cost of ur extra x"mer will
more and also some loss in X"mer is also there.

So u have to select a methode as per ur industrial
aplication.

Is This Answer Correct ?    6 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the Connected Load (kW) or Contract Demand (kVA)of mahindra nasik plant??

9393


How to know about the rating(voltage and other) of induction motor if its name plate is missing at the manufacturing site.

3327


What do you mean by lighting transformer?

989


2. What are the parameters of EHT sub-station?

2304


How to calculate the input cable rating for 10kva ups (3phase input and single phase output and also 3phase output, battery rating 65Ah)provide the formula also.thnx

2155


how we calculate torque ? how we improve it ?where torque will either motor or generator ?

2002


State the frequency for rc phase shift oscillator?

1047


how we can calcultae the short circuit level for bus bar

2169


HOE WE CAN IMPROOVE BY USE OF CAPACITOR

1905


any earth foult trip the relay but in welding time not trip by earth foult

3121


Define unilateral circuit?

1156


What is the important precuations need tocarried out while working with Electrolite in Battery PM?

1842


In constant power region of 3-phase IM torque-speed characteristics, if frequency increases flux A does not alter B decreases C increases D none of above

2184


1- XC and the RC time constant are both measures of the reaction of C to a change in ____? 2-The power factor is a numerical ratio with a value between 0 and 1 equal to the ______________ of the phase angle. 3-When V and I are out of phase because of reactance, the product of V times I is called ______________ power 4-For _____________ inductors, the branch currents can be added algebraically. 5- The ______________ power in watts can be calculated as I^2R 6-Calculate XL with L = 30mH and f = 1kHz ( I have Xl=2piFL 2*3.141592653*1kHz*30mH =188 ohms Please check) 7-A parallel RL circuit has the values, R = 5kohms, XL = 5kohms. A voltage source of Vt = 10Vrms is connected in parallel to R and L. Determine the total current, It delivered by the voltage source Vt. 8-A series RC circuit has R = 1Mohm and C = 1microF. How long would it take for the capacitor to fully discharge if it is initially fully charged? 9-A circuit has real power = 300W and an apparent power of 500VA. Determine the power factor and phase angle. 10-The time constant for an LR series circuit is T = 0.1s and R = 10ohms. Calculate the inductance L.

3291


explain Density

1069