requirements for making parallel operation of Uninterrupted
power supply
Answer Posted / rahul shukla
VOLTAGE FREQUENCY PHASE ANGLE VECTOR GROUP %IMPEDENCE
POWERRATING VOLTAGERATIO .
| Is This Answer Correct ? | 9 Yes | 1 No |
Post New Answer View All Answers
What is the formuala to calculate the rating of motor protection circuit breaker
what is the voltage regulation for unity and zero power factor?
what happen if the supply is given to the stator of the 3phase induction motor with out assembling the rotor ?
If I want to replace a 26KW Slip ring Motor with a Squirrel Cage motor & Drive (for a Hoist Application). How can I approximate the Motor & Drive HP required in new Setup.
define as synchronous generator
How to configure the drives in PLC, through Profibus commnication. And to how to address it?
What are dependent sources?
what is cause of static electricity? I experience shock when i touch metal equipment in a room ,furher check shows earth leakage showing 80ma at the DB near to the 400 MCCB?
Types of test in Switchgears, MCC, NGR and DB's how it should be procced. Can anyone give me the details here or email me to pasuvaraj.k@gmail.com
There are a trformer and an induction machine. Those two have the same supply. For which device the load current will be maximum? And why?
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
A 100 kVA , 400 v/250 kv testing transformer has 8% leakage reactance and resistance on 100 KVA base . A cable has to be tested at 500 kv using the above transformer as a resonant transformer at 50 hz . if the charging current of the cable at 500 kv is 0.4 A find the series inductance required . Assume 2% resistance for the inductor to be used and the connecting leads . Neglect dielectric loss of hte cable . what will be the input voltage to the transformer ?
physical identification of HT & LT panel
State how to produce a constant rotating field by application of alternating currents to stator armature of a three-phase squirrel-cage induction motor
What is the difference between DOL starter and star delta starter