Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Between Star-Delta & Star-Star Power transformer which one
is efficent for Earth Fault?

Answer Posted / daher

star/star because in the case of line to earth faults the
zero curret IO in delta connection transformer has no path
to leave the close loop of three phases transformer

Is This Answer Correct ?    17 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How many types of losses occur in a transformer?

1100


I am designing new project sub station with 220 kV / 11 kV, 40 MVA capacity. This project have many recifier sets, which can generate 3rd harmonics. Now I have to select vector group of This transformer. To minimise 3rd harmonics, what care should I take in selection of Transformer Vecrtor group? If it is Y-Y with open Delta tertiary then what should be the rating & voltage of Tertiary Winding?

1832


My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I -    is the value of AC fault current. t -    is the operating time of disconnecting device in seconds. K –  is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.

1817


how to find the resistance and gap volatage of the diode??

1986


How to work E.L.C.B and how to connect in circuit.

1962


what is meaning of 230volts ac 50hzs ac supply is it rms or maximum to getting ac 230v what amount of max voltage they will send

2003


What is the maximum breakdown voltage of 11KVA and 66 KVA power line and how it is calculated?

2227


which is the best institute for PLC,SCADA,DCS in hyderabad

2300


Define bibo stability.

1027


As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?

1726


what is the difference b/w ATS and HTS?

2127


if i am in front of transmission line how to know that current direction without any equipment

1696


what is the formula for calculating the phase clerance between two phases and phase to earth how to calculate the cable for a motor

1952


How DC earth leakage currents can be reduced ?

1875


what is the major difference between LIBBP & HIBBP.. which one is most preferable..

2881