Answer Posted / shravan kumar
Fouling increases the thickeness of the heat transfer
surface which results into a increased resistance to heat
transfer and hence the rate of heat transfer decreases.
| Is This Answer Correct ? | 11 Yes | 2 No |
Post New Answer View All Answers
What are some guidelines for sizing a psv for a fire scenario on a vessel in a refinery service?
hi sir/madam i need placement paper of last years of DRDO in chemical sream...... send me the question paper as soon as possible on my email address praveen.zone@gmail.com
What are the frequently asked technical questions in chemical engineering during PI?
hi i need cpcl written exam question papers if anybody pls help me
What are some good uses of low-grade steam at 12 atm and 1920c?
In Pressure Sfety Valve(PSV) 2" by pass line why given for process units.
DEAR SIR, IS IT ANY BARC TECHNICAL OR INTERVIEW QUESTION BOOK IN CHEMICAL ENGG LAST YEARS IN MARKET? ALSO GIVE THE PATTERN HOW TO PREPARE AND WHAT TYPE OF QUESTION THEY ASKED?
What are the different ways in which solids can be blended?
What step should be taken in process industries if the process variable is oscillating?
Explain the some guidelines for sizing a psv for a fire scenario on a vessel in a refinery service?
i m a frsh chemical engineer now i m confuse to attend the interview so anybody pls send model question papers to this christ_vivek33@yahoo.com
MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)
What are the various utilities of the process plant?
how will we calculate the heat of formation through electron...??
What are the disadvantages of using gear pumps?