Answer Posted / jyothi
In DC Generators AC voltage induces in armature winding &
AC is converted to dc with the help of commutator.
In AC Generators supply is taken from armature through slip
rings.
In DC Generators the armature is placed on the rotor due to
commutator.
In AC Generators armature is placed on rotor or stator.
| Is This Answer Correct ? | 9 Yes | 4 No |
Post New Answer View All Answers
ROC converges if poles and zeros lie inside a. Origion b. Z=1
What if high voltage side circuit breaker of a ehv transformer instead of lvcb? Kindly elaborate.
How to calculate earth fault current for 6.6 KV , 50 HZ , 756 Amps , 3000 RPM , 0.8 PF generator
how to calculate distance between busbar supporters for LT panel, what are the factors influencing in this design
How line capacitance & line inductance varies with increase in height tower.
how to discharge 3 phase power factor correction capacitors
why current flow to the opposite direction of flow of electrons???????????
I want to put this query to SENIOR & EXPERIENCED ELECTRICAL ENGINEERS. 1)I want to know about the control circuit diagrams for control panels. I found it difficult to understand. Is there ant booklet through which we can learn the circuit diagrams? 2)I want to learn about conduiting, laying cables, preparing cable schedules and various techniques which is the part of building infrastucture(construction field). I don't have any experience in this area. I have experience in control panels only. that's why i am not getting any opening in building infrastucture (construction field).Can I get the job in this field as Trainee Engineer? How to enter this field? I need job in PUNE
In case of salient pole alternator when number of poles are 4 or more than 4 it helps the flux wave to be sinusoid as air gap length is increased from center to tip , but if the number of poles are 2 how does the flux wave is sinusoidal?
Can we put 3 layers of cable tray while installing tray
what is allowed value of zero sequence impedancce of 6.6 kv nuetral earthing transformer ?what is the actual value
there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit
how electrical earthing maintenance done in industry?
why do we measure VIBRATION in -24vdc and why we adjust gap voltage -9vdc to 10-vdc? i am trying to get this information since 5 years, yet i haven't get reliable answer, i hope i can get from you.
Name a govt approved university which have 100% online engineering course.