what is the meaning of rms value
Answer Posted / aqeeb
it is root mean square value.(ie)take one resister give
the supply(A.C) it will produce the some heat and give the
D.C supply to the same resistance the heat will
produce.while give the D.C supply it would producethe same
heat as in A.c supply that time the D.C cuurent value shows
the r.m.s. vlue of A.c current.
| Is This Answer Correct ? | 7 Yes | 1 No |
Post New Answer View All Answers
After taking shutdown of 11kv feeder, if you see 5kv by phasing stick in the cable side, is it possible to close earth switch in cable.
Write masons gain formula.
what is the use of the puls transformer in UPS & how it works???????????
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
why does a dc machine has high efficiency while working as a generator than as a motor ..
Why i receive the GCU fault in my DG Sychronization panel . what all the factors considered for this fault .
What is Servo Ventilated Motor?
How to convert a two phase power into a three phase power in induction machine?
May I know how much values to be set for earth fault, over current and short circuit values at 11kv side? I have 11kv van 1250amps rating. Present it's taking load 80amps?
Can anyone provide with a SLD for HT panel installation for a 33KV line and distribution end has three 1.5MV transformers. Is it suitable to use OCB or VCB and also provide me the suitable rating and its connection diagram.
How much should be the load percentage for 15kva Inverter and Iinut & I output load with Calculations
What is the difference between single point and double point bonding. please kindly detail about bonding of cables.
For the requirement of a furnace of temperature range up to 1200 oC using silicon carbide rods, What is the required rate of transformer needed (please do it with all details)?
how to electronic energy metter failed in electomagnectic fild passing in the metter and which thing to defect more on metter.
State thevenin’s theorem?