why we do 2 types of earthing on tranformer ie:body earthing
& nutral earthing , what is function.
i am going to instal a 5oo kva tranformer & 380 kva DG set
what should the earthing value

Answer Posted / jayesh patel

Body earthing is used for body leakage current to earth &
not humen body harmful. Neutral earthing is used for
unbalance current pass through neutral & its goes to earth
& not effect on other phases voltages/load.

Is This Answer Correct ?    82 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

hi frenz,its aswathy.i hve aplied for the hpcl test on feb,pls send the test patern & the placement papers as soon as possible. mail-id :kjaswathy@gmail.com

1311


how many types of motor can be used in washing machine

1680


Why field rheostat is kept in minimum position while armature rheostat at maximum position?

619


How to calculate of maximum demand if given 628kw, 785kva, 0.8 p.f.

1223


operation of protection relay watchdog contact?

1938






I want to ask that is there any relation between current denesity of copper and material purity. also is ther any standard which defines the standard current denesity of material.

1469


A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1340


What is dynamo?How it works and what is the function of dynamo in a DG.

1583


which are the criterias needed to select the kind of neutral earthing(solid earthing,resistance earthing,etc.) at various voltage levels in electrical distribution?

1504


why the name trunking bus PT

2487


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

1664


The power supplied to a 50mH inductor from a 120V, 60Hz source will be

4217


define the non synchoronism of synchoronous machine in general g or m??

1440


We have received supplies of the ordered material. payments against the supplies also released. Where ST paid 4% against form C. Meanwhile it has been observed that 25% of material supplied was defective. Please suggest whether the issuance of C form from our side would be stopped till settlement of liabilities.

1463


how are reversing the direction of dc motor

1195