Answer Posted / satya
a synchronous motor is not self starting.
when three phase current displaced in time by 120 degree is
applied to the three phase stator windings displaced in
space by 120 degree then a rotaing magnetic field is
produced in the air gap. the rotor tends to allign with this
rotating field. the rotor windings are supplied by dc . so
consatnt poles are produced on the rotor.
now suppose the instant when the rotating stator field has
its north pole in line with the south pole of the rotor. the
rotor will be attracted and tend to move with the stator.
but due to its inertia before it starts to move with the
stator the south pole of the stator comes in line with the
rotor south pole. so now the rotor gets repelling force and
it tends to move in the opposite direction as that of the
stator. but again before it starts to move the stator north
pole comes in line with the rotor south pole. thus overall
the efect is that the syn. motor is not self starting. once
it is brought to the syn speed by an external primemover it
rotates at syn. speed irrespective of the load.
Is This Answer Correct ? | 50 Yes | 2 No |
Post New Answer View All Answers
What is the phase relationship between the primary and secondary voltages of a transformer?
How a band pass filter is constructed?
please suggest some good universities with low cost iam in totally full confusion so please help me my profile gre 283 and ielts 5.5
how can i improve the power factor in domestic (230v)
we all know voltage is a force(emf), and the force always devides if 2 or more than2 loads are there but why does the voltage remains same is parallel, it must devide na ???
What are the basic components of the feedback control system?
what do u understand about FACTS? how they are useful?
What is CCT (Correlated Color Temperature) ?
why i can not use thimble on capacitor duty contactor
reason of diode failure in alternator
in ring main system we use the isolater b/w transfer bus and main bus if we r not use isolatar than wat will be the effect in our sys.
what is the difference between dry and wet type of 132kV terminations. which one is durable
What is resistance reading of earth copper rod with grid and without grid?
what is the Connected Load (kW) or Contract Demand (kVA)of mahindra nasik plant??
what is a composite error in current transformers, why occurs & in which it will occur i.e, either metering ct/ protection ct