What is the effect if power factor is above 1 or unity.
Answer Posted / sayed
at unity power factor all active power used so it is real
power and reactive power will be zero so losses will be
zero.
If power factor is above one reverse current will be
occured i.e motors will works as a generator.
| Is This Answer Correct ? | 10 Yes | 12 No |
Post New Answer View All Answers
Why compensation is necessary in feedback control system?
What are the applications of different multistage amplifiers?Plz also write advantages of these amplifiers? Thaaaaaaaaanx
what are different types of electrical windings? i know the distributed winding ,concentrated winding etc but i want some detailed information, in what condition we will use distributed,concentrated windings what are the difference between them which is best, how induced emf changes by using different types of windings 20 hours ago - 1 week left to answer
i applied for c licence with my one year apperents trainee and i have attaced with A grade contractor company experiance that is for 14 monts experiance this document is sufeicant for c licence? pls tell why they rejected
Ceiling Fan and Storage type water heater. Discuss
What will be electrical cost per sqft for IT building (basebuild and fitout)and for residential township?
A 100KVA SINGLE PHASE TRANSFORMER 10000/200V,50HZ REQUIRES 300V AT HV SIDE TO CIRCULATE FULL LOAD CURRENT WITH LV SHORT CIRCUITED.THE INTAKE IS 1000W.THE % OF REGULATION ON FULL LOAD AT 0.8 PF LAGGING WILL BE HOW MUCH AND THE SECONDARY TERMINAL VOLTAGE ON 0.8 PF LEADING WILL BE
Hi everyone, I'm Lachuu, recently joined automation company as PLC Engineer. I have certain basic question, I request all big gurus and seniors to answer these question. Because this will be very helpful to me as well starters like me. How to design a control circuit (ex: pick & place - my current project) Yamaha robot PxYx series controller RCX222, using 6 cylinder double acting, plc keyence kv p16r 2 expansion unit for input and output each. How to select panel terminal mcb elcb powersupply. My main concern in some projects how to select dc power supply, mcb rcb(I came across dif bt b c d curves, but stil confusing, pls help me :-(. I would really appreciate all who are going respond to this question.
Does the direction of rotation of d.c. Shunt motor would get reversed if the armature current and field current both are reversed?
why need to be maintain power factor for industrial customer?
What is the maximum breakdown voltage of 11KVA and 66 KVA power line and how it is calculated?
what is the safety of voltage power transformer(2250KVA0
How to Decide the Location of Earth pit for Compressor in Oil Depo? and How to measure the resistance of earth pit Pls explain me with the help of Circuit Diagram?
what r substations?what r there work?why voltages r incresed and then reduced during distribution of power
what is earth-fault?when it occurs? to check where it occurs what type of test should we do?