Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what will happen when choke in tube light circuit was not
working???

Answer Posted / pavan

Choke will increase the voltage which it ionises the gas in
the tube.With out choke the tubelight will not glow.

Is This Answer Correct ?    2 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

salam&hi, i need to know about how can i calculate an enough current for the new building before i submit it to the suppliers

2078


What is Scheme Test of High Voltage Switchgear. Which tests it includes.

2408


some basic standard questions on transformer.

1788


In aerodynamic turbines which element is NOT there a.stator b.compressor c. Fuel intake system d.fans

2127


What is advantages of VSCF wind electrical system?

2325


State thevenin’s theorem?

1081


explain the Trip supervision circuit

2145


In synchronization circuit what is the function of Interposing voltage transformer(IVT)and Reverse voltage transformer(RVT)

11817


i have seen one 8.4 MW synchronous motor in a plant located in bellary it is fixed with brushless rotary rectifier ,anybody can explain its start up principle

1976


Differentiate between Zero and Negative sequence current

1895


what may the reason for vector shift in a generator?

1865


What are the three major categories of error?

1214


how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

2209


What is the importance of counter based plan & how is it scheduled?

2006


what is the difference between 50 hz freq. and 60 hz freq.? which is better and economic in them ?

2281