While starting a high capacity motor, it takes 6 times the
full load current. Why it doesn't trip relay or CB's in
that network?
Answer Posted / sunthosh080
usually when you see the relay technical details there will
CLASS type (5-30)
When your motor is taking 6 times for 5 sec you have to
select 5. So that your relay doesnt trip during this and it
depends on the application also.
If it fan application , then it would be around 15-20.
If the relay is tripping during motor starting then it
CLASS problem.
| Is This Answer Correct ? | 0 Yes | 4 No |
Post New Answer View All Answers
Can any body tell me the different types of LT cables & their application.
we have require a Motor (1500kW, 6.6kV, 50Hz) which shall operate at 1500rpm during 30min and after it shall run on 500rpm during 15min. The same cycle shall be repetitive during the whole working days. Which method is best and economic to achieve such type of task. VFD, VVFD, Pole changing motor etc.
to vary valtage from 0 - max a variac is necessary . so how to design for high power applications nearly about 200KW power
How to calculate VCB rating for 33KV ,25 MW Power line?
Which types of gate insttaled in static switch. Please give me answer.
power transmission pole used one support , that only for support or earthing
why ten delta testing is carried out on power transformer
What Should be the value of Vector Surge angle at Tripping and how to calculate it?
How to calculate approximate load loss of a distribution transformer by knowing %ge imp of transformer?
As we know induction squirrel cage motor torque Directly praprortinal to applied voltage in star connection & delta also. If I connect 55KW Motor to DOL starter in load condition does motor withstand the load & what will be the current withdrawn ? motor will not fail ?
why do we need to use 3c+3e cable, normally i select only 3c+e cable and i think it is enough. pls explain the usefull of 3e cable ( in this project the earthing system is well done)
What is meant by reactance voltage?
when ac current flows thru d coil of a contactr,it energizes,magnetic field attracts d contact of the coil...nw wont dt ac current in d contct induce current back on to d coil thru mutual inductance leading to high currnt in d coil
There is air in a room . the top and bottom of the room are at constant temp. T1 and T2. DRAW THE temp profiles if a. T1 greater than T2 b. T1 less than T2
1)we have 1000 cfm Blower,Dia-1Mtr,Velocity of air 94 m/s 2)We have Natural Air velocity 94m/s 3If i Put Wind Mill in natural air ,speed is 94m/s Then it will generate Assume 100kw 4)If i put same wind mill across the Blower,air speed is same 94m/s now the Question is Will it generate 100 kw?