Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how to calculate capacitor bank value to maintain unity
power factor plz xplain with some suitable xample?

Answer Posted / er. ankush miglani 9718151073

KVAR= KW(TAN(COS(-1)#e)- TAN(COS(-1)#d) )

#e= EXISTING P.F.
#d= DESIRED P.F.

Is This Answer Correct ?    35 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I HAVE A INCOMING 100A MCCB TPN 25KA, CABLE LENGHT OF 80M 70MM CABLE SIZE FROM MAIN SUBBOARD TO NEW DB.BASE ON THE FAULT LEVEL SETTING OF 45KA.I WOULD LIKE TO FIND OUT 25KA ENOUGH KA. APPRECIATE IF SOMEBODY CAN ASSIST ME WITH FORMULA FOR THIS. FRM: JEFF

3976


what is meant by moulded case circuit breaker ?

2125


STATE USE OF ARC RUNNERS & SPLITTERS ?

1876


What is effect of harmonic current (Draw by VFD) on power system/ electrical Equipments ?

2008


state types of reflectors in illumination engg. ???????

1871


Define what is difference between fuse and breaker?

1113


What are the differences between single phase and three phase?

1984


Incoming line 11kv And transformer capacity is 2500kva. Consumption load is 1300A. Then fuse capacity is 11kv line.

1628


What is the necessary and sufficient condition for stability.

1083


how to produsing geretor power

2150


what is meant by residual over voltage & residual earth fault ?

8849


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2094


What is the loss of transformer of 220kv/11kv, 63/80 MVA and 18.05% impedance

1939


how the speed of the gets motor regulated. does it draw the same current on the all speed level.

1932


What is frantic effect?

1198