what is the meaning of rms value
Answer Posted / general
The root mean square value of alternating current is equal
to the value of the direct current which, flowing through a
resistance, produces the same heating effect in the
resistance as the alternating current does.
| Is This Answer Correct ? | 6 Yes | 0 No |
Post New Answer View All Answers
please give me all the Alarm .Trip ,Safety Relays & Conditions of Chiller mail me on ashokbabunhce@gmail.com
what is the minimum recommended leakage current of an earthed cable connected to the body or skid of an alternator
DIFFERENCE BETWEEN NORMAL TRAFO AND THRISTER TRAFO?
What is different type of Electrical curve and how it protects the equipment's while up-normal situation?
i want bhel placement paper for electrical if anybody having pl send to my id kavitha867@myway.com immediately
Brief me about maintenance planning & sheduling of machine tool.
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
why lightning arrestor are made in two stack of insulator but why not cvt
what is sevice settings for mccb?How can be it setted?
what are the usual topology of transformers at different substations in the power system and why that particular topology is choosen. what are the limitaions of that topology?
What is block diagram?
If two Transformers are connected in parallel having impedance of 50KA in both transformers will the impedance increase or decrease after connecting transformers in parallel?
3 shows a 415 V, 3-phase generator supplying a 3-phase 415/110 V transformer. Draw the individual and combined impedance diagrams to a base of 10 kVA. Determine the system fault kVA and the fault currents at the 415 V and 110 V busbars for short circuit faults on the transformer input or output terminals. Work in p.u. values of impedances.
how many types are their in switchyard or substation(like D,I TYPE), what is differant between them
Why Stabilising Resistor used in REF circuit ?