Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the relation b/w KW and KWH? plz explain with
example.

Answer Posted / bharat patel

kw is maximum capacity of power of drive or motor which is
multipication of voltage and current like for three phase
drive, P= root 3*v*i*cosQ.
where P= kw,
V= voltage-415v,
i= current Drawn by motor or drive

Kwh means hoe much power consumed by drive in houres
means Kw*H= kwh

Is This Answer Correct ?    14 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

State how to produce a constant rotating field by application of alternating currents to stator armature of a three-phase squirrel-cage induction motor

2481


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

2018


why do we need to use 3c+3e cable, normally i select only 3c+e cable and i think it is enough. pls explain the usefull of 3e cable ( in this project the earthing system is well done)

2451


In the formula : Knee point voltage = Burden X alf / class, Please inform what is alf? regards Shashidhar M.R.

4226


Where can I get CPWD electrical specifications & Shedule of rates? Please help me

2247


how to find out cable size if load is 2800 watts, 230 volts AC supply and load distance is 1800 meters

1607


What is the loss of transformer of 220kv/11kv, 63/80 MVA and 18.05% impedance

1991


USE OF 8 WAY PAN ASSEMBLY

1954


what is the reactance,capacitance & impedence electrical armoured & unarmored Cables.

2197


In a large office how do we calculate required number of light fittings, assuming fittings are 4x18W or 2x36W fluorescent fitting ?

1870


redundant connection in contactor?

2495


I Need standard operation procedure(SOP)for 500kva Oil type transformer oil filtration & Procedure for IR value checking.

2887


oltc of a transformer, how it works? and what are the equipment consist of describe briefly?

2025


how to calculate the surge level of surge suppressors related to the SF6 cicuit breakers?

1962


HOW TO TEST A LIGHTENING ARREST ER ?

2198