Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is relation betn. KW & KV?

Answer Posted / tauseef tarique, engineer(e)

kV (Kilo Watt) is the unit of measurement of electrical
power. While kV is the unit of measurement of voltage
(potential difference).
for the three phase supply
kW= 1.732xVxIxcos phi
where V= Voltage
I= Current
Cos phi= power factor

For single phase supply
kW= VxIx cos phi

Is This Answer Correct ?    16 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

iam using DM 3251 voltmeter(1 percent accuracy)for 11KV system PT ratio is 11KV/110V.can anybody explain what is the max and min voltage deviation.

2205


how much value of resistance should connect to 15 kw, 6 pole 3 phase slip ring induction motor having RV-240, RA-42.

1865


which one is more efficient, torq, power & ecnomy with the same frame size AC motor / DC motor?

2121


What is the types of HT motor testing

3491


Is it possible to obtain 480v or 550v in single phase output by giving the input to 230v to a single phase torodial type transformer without using a stepup transformer?

1950


why don't we use the generator as a motor? and what will happen?

1832


if a 3phase 100kva distribution transformer , 400 v,50 hz, 4-wire system is loaded at 160 k.w mostly 1-phase Lighting & Airconditioning split a.c load what will be the net effect on the power system in terms of voltage, powerfactor, current , efficiency of xformer

1842


what is the purpose of high speed earth switch in gas insulated substat

2932


application s to shunt coil

1865


What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.

2001


what will be the maximum winding temperature of 6.6kv HT motor 450kw, Full load current 49A. 50Hz Frequency.

3171


how to calculate the power factor when instantaneous voltage and current has harmonics in it ?

1910


what is a composite error in current transformers, why occurs & in which it will occur i.e, either metering ct/ protection ct

1780


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?

2390


im working in one private compeny in gujarat. i was complet diploma electric in 2010 from gujarat technical board. now i want electric supervisor licence in gujarat but i dont't know when i apply? plz give me address of the licence dippartment office in gujarat. gandhinagar

1798