What is the function of earthfault relay?
Answer Posted / micro power system, bangalore.
Actually earth fault relay's function is,it calculates the
vector sum of all the three currents flowing in R Y B
lines. If the vector sum is not zero then there is a fault
current flowing in particular line. since these lines are
connected to load say generator then, more than the rated
value of current flowing through windings ,hence windings
will damage so to prevent these type of damages EFR is
used.
if any comments pls send to shreeshara@gmail.com
Is This Answer Correct ? | 123 Yes | 18 No |
Post New Answer View All Answers
diff.between servo motor and ac motor
Why we are using Isolation Power Transformer inplace of commercial power transformer? What's the difference between them?
while starting a liquid starter ,is there any volage drop on water/soda on tank.can we touch the tank on starting?
generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...
how to calculate the Neutral transformer impedance?
why the NGR (neutral grounding resistor) always OFF during DG off?
Difference of induction motor & servo motor ??
why should the lowest unit of a testing transformer ( cascaded transformer ) have higher power rating??
Swg formulae
How eddy current generation support the idea of train braking?
I PURCHASED A DEISEL GENARATOR SET OF AVR TYPE& RATING 125KVA BUT SOME TIMES THE OUTPUT VOLTAGE IS FLUCTUATING WHAT ARE THE PROBABLE REASONS GIVE ME
How the capacitance og capacitor volatage transformer is decided?
I have an existing old MCCB. ABB Model SACE, the rating are: Ue = 660 volts, Iu =1250 Amps, 3 poles, Ith (max) =800 amps at 45 deg C. I need a circuit breaker for my 3 phase motors, 380 volts 60 hz. the supplier required the minimum ampacity of the breaker to be 911 amps. can i use this breaker with rating of Iu =1250 amps but Ith = 800amps maximum?
why ct's&pt'S out put called as burden,why compelsary short ckt the secondary of ct's while removing the burden?
Which contains in POLE ASSEMBLY of a 11KV Kirloskar-make SF6 (Model No-FP620A12)? Will u clarify with drawing?