why power generate in 33 kv it will be step down by 11 kv .
Answer Posted / v.chandrasekharreddy
for generation of 33kv we require large alternators thus
increase the initial investment of plant.reduse the voltage
fluctuation
| Is This Answer Correct ? | 2 Yes | 9 No |
Post New Answer View All Answers
If rotor works in clock wise what happens
how we control automatic generator i'e with to supply (main supply and local generator) when the main supply was break to supply the local supply automatically to begin supplying power.I now this control circuit is the combination of contactor time delay contactor switch and overload relay .but my question is how we combine those component thank you
what is the necessary of using inductance property in transmission lines even through resistance is used to opposes the high current flows in that?????
What is the drawback of class b amplifier?
WHAT IS FAULT CAPACITY OF HT MOTOR TERMINAL BLOCK? ANY BODY HAVE ANSWER PLZ....POST IT.
Details about Flux Compensated magnetic Amplifer starter for motors
why genarator genarating voltage 11 KV?
in my industry we are using 3 step up transformers for induction heaters..i.e 415/580v and other are 11/440v.in power consumption does a step trnsformer makes any difference compared to step up?? plz explain
What are the advantages of autotransformer?
what is the maximim current drawn by 1 phase and three phase welding machine
A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.
if a number of plc s are there then how many modbus to be used
I have an existing old MCCB. ABB Model SACE, the rating are: Ue = 660 volts, Iu =1250 Amps, 3 poles, Ith (max) =800 amps at 45 deg C. I need a circuit breaker for my 3 phase motors, 380 volts 60 hz. the supplier required the minimum ampacity of the breaker to be 911 amps. can i use this breaker with rating of Iu =1250 amps but Ith = 800amps maximum?
Why we specify TNC switch with 1NO 1NC ,2NO 2NC ? how we get connection.?
how to test reverse power trip?