Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why the generating voltage in India is 11kV or why is it be
transmitted as multiples of 11

Answer Posted / johince

Multiples of 11 has no role decoded from form factor and anything
like that (I believe). the relation to form factor is just a
coincidence.
In early days when technology has not advanced this much, the
transmission lines consumes around 10% of the total power
transferred. Normally loads are designed as multiples of 10 or
100 KW. So the generation done for required load power +
transmission loss. ie 11KW, 110KW etc. So generated voltage also
was designed as multiples of 11.
Hence the insulators has to be designed for these volatges and
hence the form factor coincidently derived as 1.11.

Is This Answer Correct ?    27 Yes 13 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How does a transformer contribute towards the widespread popularity of ac system over dc?

1105


Differentiate between ideal and non-ideal voltage sources?

1088


What are the main advantages of bode plot?

1253


How can we calculate the KVA rating of a Distribution transformer from its core details?

2071


What are the different losses In a de mac1une'! t.xplam

2748


temp of cast resin 1500kva tx formerwent up to 138.c but came down very fast to about 100.c within 20 mins when load was reduced from 70% to 60%

1924


why T/F winding temp measurement cts are odd secondary current ie,109A/1.2A/1.4A?

1866


In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes

808


which phase is preferred for connecting 1 phase vt used for synchronizing OHL? WHY?

2047


Discribe type of fault in DOL and stardelta startor.

2240


5- What is the task (function) of the excitation and isolation transformers in power plant? 6- What is the task (function) of LCI (A), LCI (B) and LCI (COS) in power plant? : LCI (A) and LCI(B) are load commutating inverter for generator turbine starting. , LCI (COS) is load commutating inverter change over switch

3819


What are the basic properties of signal flow graph?

1220


How to select the earthing transformer,for DELTA TO DELTA TRANSFORMER OR ALTERNATOR SIDE.Pls post your answers and calculation.

2377


In cable sizing calculation (determining the max route length of cable) why we choose the shortest length between cable length of full load current Iflc & starting current Istart?

3319


I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?

1755