Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Does increase or decrease of reactive load affects the
Voltage.

Answer Posted / moody

of course
when load pf is constant and the load current increase the
t.v decrease " lagging p.f"
at leading pf the t.v increasing
this occurs in synch generators
if the load is constant but the p.f changed or varried
the same operation happens in lagging , leading respectivly
thanks................

Is This Answer Correct ?    15 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WHAT HAPPENED DC SERIES MOTOR FIELD WINDING OPEN. CAN POSSIBLE.

3873


What is the meaning of HT Trivector Meter ?

2433


condition Autotrip facia come on control panel of electrical transmission line?

1558


My question is abt backlog.I had dropped one subject in my second year, and completed this subject in the 3rd attempt, so how many backlogs i have got?1 or 3?plz sujjest the answer as soon as possible

2080


after how many spot we must chang secondry cable in portable spot welding gun?

1921


how slip power recovery system work

3007


how do i work out the Amps of a incommer if i am running 1 37 KW motor and a 0,75 KW motor and some solinoids

1878


how oil in the MOCB was reduced compared with OCB? what are the features of the MOCB?

2757


Define cuttoff frequency?

1051


what is the safe meggar values for motor, transformer HT, LT and Cables? IF we want to replace I/C bay at our 220 kv substation which is of 140 mw load capacity bay to be replaced by 400 mw capacity bay.other than CT(1200/1) what are the other equipment i have to replace. why we generally use 3.5 core cable or in other word 1/2 core for neutral and also confirm me that in balance conditiob(3 phase)current in neutral will zero

2253


What is I to C?

2127


what is negative and zero impedance in 3 phase induction motor ??

2147


How much minimum insulation required between 11kv/3.3kv transformer windings?

2411


Both generator parallel condition shared load equally but one genrator taking ampere more than the other what are all the causes to make like this

1726


what does mean of RCT and STR in diffrential CT?

4213