Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

which type of motor is suitable for lift?

Answer Posted / sanjeet swarnakar

cumilitive compound motor

Is This Answer Correct ?    24 Yes 10 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Which type of a.c motor is used in the fan (ceiling fan, exhaust fan, pedestal fan, bracket fan etc) which are find in the houses ?

1017


What is transister define the transister ammiter ,base, colector.

2206


List few applications of d.c series motor?

1117


what's the simultenous maximum demand (SMD)..what the diffrent MD and SMD?

2493


How to calculate approximate load loss of a distribution transformer by knowing %ge imp of transformer?

2200


in wind mill use 2100 kw asychronous generator ( induction generator ) rotor voltage : 3300,stator voltage : 690, rpm : 1511 type : MRL063E04 ' we check rotor resistance magger value found following. R-EARTH - 00 M.OHM,Y-EARTH-34 M.OHM,B-EARTH- 33M.OHM R-Y: 31 M.OHM, Y-B: 00 M.OHM,B-R :33 M.OHM HOW CAN I TAKE DECISION?pls ans. quickly

2288


why we are using earth pit in sub stations.?

2135


What is kirchoff ’s current law (kcl)?

1067


why all the feeders are designed in a particular manner ... is there any reason for that???

1939


I want to ask that is there any relation between current denesity of copper and material purity. also is ther any standard which defines the standard current denesity of material.

1943


If we use 250A MCCB as a incomer in Control panel for a fault level of 50kA for one second ,assuming temperature rise from 85 Deg. to 100 Deg , Then what will be the Aluminium Bus-bar size for 250A MCCB? Explain in detail.

2330


it is possible to rotate the DG engine dc starter with wrong polarity connections? why?

2234


Will any motor burn if voltage provided is lesser than the rated voltage???? If yes, then how is speed control possible with voltage control

2149


3phase cable calculation formula by motor load

1498


How to test REF relay testing for LV panel as per Kahramaa standard?

4920