Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

I have installed capacitor bank at secondary transformer.
cos phi is increase. but on load (far from transormer), it
still poor. Can anybody explain it??

Answer Posted / heamkumar

Capacitor Bank is used to improve the Power Factor.
As you said, Pf will increase only in the incomer side.
Because you have connected the capacitor bank in the
secondary side near the incomer. So if you need to improve
the pf near load, you need to place the capacitor bank near
the load, but according to the load. So if you put the
capapcitor banks near the load side, power factor will
improve not only in the load side, but also in the incomer
side.

Is This Answer Correct ?    11 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I want to know Electrical Circuit?

2167


Define availability (operational)?

1155


When will you multiply and devide with derating factors to the actual value while sizing the cable?

1945


What are the common sources of energy?

1103


HOW THE OLTC TRANSFORMER SAVE ENERGY IN COMPARISON TO OFF LINE TRANSFORMER AND IS IT ECONOMICAL TO REPLACE THE OFF LINE TRANSFORMER TO OLTC TRANSFORMER

2199


how to determine Sq.mm size of finolex power cables.

2007


What is servo motor? what is its purpose?

2057


why we use circuit breakers for switching instead of normal switching device?

1877


- two pumps must work with them at the same time but if the first pump start the second pump  must delayed for some time to start  also , with motor rated power = 90 KW and rated voltage = 380 V and rated power factor = 0.85 lag please draw the power and control circuit for it and determine all circuit components parameters that you use it

2746


how to caculate cable size for diff types of loads? if anyone know the calculating procedure please tell me

1439


Does magnetomonopoles exists? one maxwell equation strongly suggests no, but how about their existance in plasma?

2004


What conditions are required for transformer to operate at low frequencies ?

2009


What is d main advantage of using double circuit 3 phase transmission ?

1936


what is the effect of change in supply frequency on load angle of synchronous motor,all other parameters remaining same?

2357


what is the AC Plant and how can do the work with parts and picture tell us 150 Tr

2030