Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are the different types of Protocols? & their applications.

Answer Posted / rajesh j

PROFIBUS - Siemens products
MODBUS - Modicon products
RIO - Remote I/O bus (general)
DH+ - Allen Bradley products (Generally)
FIELD BUS - Open bus communication in DCS
FF BUS - Foxboro Field Bus (foxboro products)
CAN Bus - ALSTOM products (Pls confirm)
RS232/ RS485 /RS422
HART - Rosemount products
BT - Brain Terminal for Yokogawa products
Others - Ethernet
TCP/IP

Is This Answer Correct ?    44 Yes 30 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is loop1 and loop2 in MTS LT?

4712


when a magnet is heated?

2029


what is the diffrence between pressure safety valve & pressure relief valve....pls

2219


Explain the working principle of lvdt?

1239


What inherent design and operating principles are included in a modern control system to use predictive maintenance practices to increase overall system reliability?

2141


I have a Control VAlve having size of 2 ".Only the known parameter is Pressure drop . Its 2 Kg. Then How to calculate control valve sizing means Cv.

2402


Please can anybody help for control valve sizing step by step procedure?

2191


anybody having Qatar Petroleum questions for instrument Technician offshore ....please send me

6089


How to interfacing microcontroller with a DC motor

2106


I want to apply for the universities in US,but i got the GRE score of (650+300=950)TOEFL 69/120.Is this score sufficient for applying universities please i am married i need to go to US because my husband didn't get H1 yet.please send me suggestion

1920


How the sizing of the analog signal cable is calculate?

2602


Can I calibrate the Electromagnetic Flow Meter on line and How.

2008


Lux meter is the measuring device to measure the lux level of lighting fixture. in industrial sector two types of lighting fixture is being used as street lighting purpose 1. HPSV (Sodium) and 2. HPMV (Mercury). HPMV having white light which is an combination of red, blue and yellow colour, while HPSV haivng Yellow lighting. in HPSV red & blue colour will be absent. during measurement of the lux level of HPSV and HPMV fixture. 1. Lux meter can measure the actual lux level of both fixture? 2. or it will show false reading for HPSV fixture light as it has only yellow light present. please give me answer

4712


Good evening all I need a small favour regarding reliance paper i wanna probable sample papers(e&i) of reliance. if any of u have any idea about dis then plz mail me back.i belongs to electronics and instrumentation engg.so i need e&i papers. thanking u....

2134


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1983