can induction motor run over the rated speed ?
Answer Posted / padmanabh thakur
wheninduction motor run over synchoronous speed then it
behave as generator.
this can be done by using flux control or by external means
| Is This Answer Correct ? | 5 Yes | 2 No |
Post New Answer View All Answers
can any one tell me about the Extra low voltage systems?From where we give supply to these type of systems??
please suggest some good universities with low cost iam in totally full confusion so please help me my profile gre 283 and ielts 5.5
which type of stability limit is higher,steady state or transient? why?
what is basic difference betmeen normal & flame proof motor??
what is gas turbine intercooling ?
How to design inductive load for 3 phase 440v and maximum 5 amps for star or delta? Can we use a 15kW, 1450rpm motor for 15kW, 960rpm apllication?If yes.how......n.if thesame motor used what`s it`s sideeefect.
why capacitance effect is predominant in underground cable transmission and inductance effect is predominant in over head line transmission?
why should the primary of transformer be connected in delta in a heat run test?
The height to which the liquid in a tank to be maintained for a certain constant velocity?
what is reverse power relay brief explanation and in b/w where it is connected
What is the maximum No. of out going mccbs permitted from an LV distribution paqnel? What is the ampere relation between incomer and out going switch gears/mccbs?
How to megger test 11 kV cable and the acceptance IR value
What should be the Sandwitch type Al. bus bar capacity for 2 M.W.Gen. set, having continuous full load current- 3463 Amps,ambient temp.- 50 Deg. C., Required temp. raise-20 deg.C., it will run 24 hrs, 365 days on full load, required highly reliable.
How to select the earthing transformer,for DELTA TO DELTA TRANSFORMER OR ALTERNATOR SIDE.Pls post your answers and calculation.
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.