how much percentage(%) of load can feed in power
transformer?
Answer Posted / heeth
usually power transformers are designed to run at an
optimum efficiency nearing to full load rating. So usually
power transformers are loaded around 90% of their rated
value..
| Is This Answer Correct ? | 35 Yes | 2 No |
Post New Answer View All Answers
WHAT IS SUBSTATION & ACCORDING TO VOLTAGE HT,EHT SUBSTATION EXPLAIN IT
In constant power region of 3-phase IM torque-speed characteristics, if frequency increases slip A does not alter B decreases C increases D none of above
can any one suggest paper presentation topies for electrical engg?
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
if in 3-phase system voltage=440V,frequency=60Hz, current=400A. then if it is single phase then current=? and if it is single phasing then current=?
To prove the capacity of a 10MVA transforemr with 6.5% impedance by a short circuit test how much power is needed to inject an impedance voltage if we have to arrive for its rated current?
What is the basic principle of operation of alternators/dc generators?
Please clarify 1. Icw: rated short circuit working withstand capacity 2. Icu: Rated ultimate breaking capacity 3. Ics: Rated service short circut withstand capacity 4. other specification of ACB
What is time invariant system?
What are the conditions to be satisfied for parallel operation of dc generators?
In Dyn11 power transformer if any one of the 3 phases connected to earth in star connected side then please explain effect of the current flow in delta connected side of transformer.(In this case if one phase is shorted to ground in star connected side then we observe the current flow in two phases only not three phases in delta connected primary side. Please explain why it is so?)
plz explain the auot-reclosing circuit in electrical engineeing
how to select battery for 15 KVA UPS with formula
Why are the laminations insulated from each other?
What is the permissable nutral current of three phase system as per IS standards?