Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why not implimenting power factor in Diesel generator

Answer Posted / bhupal singh

Power Factor is the property of load. Generator is a source
of power. So it can not be corrected thru generator. However
Synchronous generators can regulate power factor by
adjusting it's excitation current.

Is This Answer Correct ?    4 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

2005


For a three phase induction motor, what will be the effect on motor if the neutral of the system is shifted to say 20 deg.?

1809


I am having a 1500 KVA transformer whose secondary current is 2086A and my connected load is 1000 KVA, I am having 400 KVAR APFCR for PF improvement what ratio of CT should i install in LT EB Bus to get optimum PF improvement?

1733


Can an inverter be used as a converter? How?

1928


how to decide no of electrodes for 1600A LT Main incomer panel

1634


What are the conditions to be satisfied for parallel operation of dc generators?

1073


what is the purpose of high speed earth switch in gas insulated substat

2973


bsnl tta exam question

1860


What are the main advantages of generalized error co-efficients?

1152


Brief me about maintenance planning & sheduling of machine tool.

2119


how dia of wire and angles are calculated for overhead shielding wire to protect substation equipment from lightening strokes???

2010


why we used dc supply for field in dg set

2365


why sielent pole is used only in hydro generators and not in turbo generators

4161


Which motor is 3.3 or 11kV more reliable, in terms of efficeancy,maintenance, reliability.

2094


if a.c supply is given to the motor,, what happen?

2131