tell 2 reasons for why only copper is used in domestic
wires& only alluminium in transmission lines ?
Answer Posted / deepakeee
1.alluminium is cost wise less then copper so used in
transmission line
2.pure alluminium not directly used in transmission because
it have low mechnical strength in india we used Aluminium
Conductors Steel Reinforced (ACSR) because it have high
mechnical strength.
1.copper have low loss so we used in domestic purpose...
2.when compare to alluminium ,copper have good conductivity
but availability is less...
| Is This Answer Correct ? | 49 Yes | 1 No |
Post New Answer View All Answers
I have done my m.tech in electrical engg discipline. Can any one please suggest me how should I prepare for getting into phd in iit or nit.How should I prepare for getting into lecturership
7- What is the Dissipation Factor and the difference between it and Insulation Resistance Test? 8- What is the task (function) of DC and AC reactors in power plant? 9- What is the task (function) of (open delta with earthed) in some types in transformers? 10- What is the base of the selection of the vector group in transformers? 11- What is the zig-zag transformer and its function by drawing in large detail? 12- What is the polarity ? 13- Why we make short between phase(R) in high side and phase (r) in low side in vector group test? Where High Side ( R ,S and T ) and Low Side ( r ,s and t ). 14- What are the time on delay and time off delay? 15- What is the vector group? 15- What is the task (function) of different types of vector group such as Dyn11 , Dd0 , YNd1,……..,?
How do i right a ladder diagram that has 1 actuator that performs a full stroke followed by a half stroke
Which type of motor is used in trains, what is the rating of supply used explain working principal?
What are the advantages of thermal power plant?
Why need 3phase machine double earthing?
what is cathodic protection and why it use in industries?
Define peak overshoot.
hi frnz,can somebody give me any project work? i am a 2nd year student & interested in practical works...plz give me some projects
what is the operating time for LBB and how does the LBB relay realise whether cb is opened or not?
WHY TERTIARY OF POWER TRANSFORMERS IS LOADED WITH EQUIPMENTS LIKE CT,PT,ISOLATOR AND CB
what is the requirement regarding earthing of Single conductor with AWA
I have 2500KVA transformer delta/star,13.8KV/380V provided with LV 4000A breaker. Already I have 2300KW motor feeder with a full load 90%. Is it possible to connect another 1600A from that breaker? If so how the calculation is done?
why actual valve timing diagram is different than ideal valve timing digram of a 4 stroke engine?
How to work meggar?