WHAT IS THE DIFFERENCE BETWEEN PLC AND DCS

Answer Posted / satishpatel-bilimora

plc is a progrramable logic controllers & dcs is a
distributed control systems. plc is a on/off controller.it
controls the only machine on or off. dcs controls the many
plc at the time.

Is This Answer Correct ?    62 Yes 107 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the diffrence between digital signal processing and discrete signal processing?

1583


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1446


Difference between ultra sonic flow meter

1553


Why all the drains(Gland sealing,ESV,Casing inlet etc) are directly connected to the flash tank instead of hotwell of the condensor in the power plant? My Email Id:naba02222@gmail.com

1858


dear friends, i have seen flow as the selection critriea in presure guage (bourdon tube) and i would like to know what is the relation between flow and performance of pressure guage other parameters i found in the data sheet are pressure max. 1ksc temperature max. - 50 deg c line size - 80NB operating range - 1ksc pr. guage range - 0-2 ksc thank u,

1728






how to connect transmitter measuring sulfur process? 1-by using long impulse line or 2- by using coated short impulse line

1581


hye SAM acn u send your e mail id, so that i can solve my query through e mail?

1811


What is the basic difference between Modbus and CAN Open Protocols

5814


How is PH sensor works ?

1571


what is the calibration procedure for magnetic flow meter @ onsite

1202


How u will setup SPI(2007) on Citrix Server (Thin Client Mode)? Plz Justify?

1590


Please tell me details about Sox,Nox,SWAS analyser????

3282


model question paper of instrumentation for Jindal GET 2010.plz reply sudhanshukumar08@yahoo.com

1900


where are following valves are applicable to install. can any valve be installed any line. globe valve butterfly valve boll valve gate valve

1247


In bently nevada vibration monitoring system,what is the reason to maintain the Resistance of the probe + extension cable equal to 95 ohm? If possible explain the basic principle of measurement with detail electronic circuits.

2486