How you take care of a motor from over loading and what are
the different overloading ratings of different motors?
Answer Posted / kiranbabu
Motor
Rating Motor F.L.C in Amp
0.25 KW 0.4725
0.37 0.6475
0.5 0.9625
0.75 1.3125
1.1 1.925
1.5 2.625
2.2 3.85
3 5.25
3.7 6.475
4 7
5 - 5.5 9.625
7.5 13.125
9.3 16.275
11 19.25
15 26.25
18.5 32.375
22 38.5
30 52.5
37 64.75
45 78.75
55 96.25
75 131.25
90 157.5
110 192.5
132 231
150 262.5
160 280
200 350
250 437.5
| Is This Answer Correct ? | 1 Yes | 5 No |
Post New Answer View All Answers
In Indian Household, generally we receive 220V AC single phase supply. But AC has 2 phases, +ve & -ve. So in +ve half cycle current is flowing...so what happens in the -ve half cycle?? Please illustrate.
what is the difference between 50 hz freq. and 60 hz freq.? which is better and economic in them ?
Why is better to have a minimum ceiling voltage of 250% than 160%?
how to avoid electrical shock how capacitor store charges wat are the speed control of induction motors state faradays law flemings left hand rule what is rotary converter wat is transmission and distribution what are the sources of energy abrevation of acb,vcb,sf6,igbt what is output equation of transformer which test copper iron and iron loss are calculated what is eddy current draw a single line diagram (10 marks) draw direct online starter(10 marks)
During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP
What is icu and ics in Acb and how many time icu or ics passes from breaker?
Why corona leads to production of Ozone and glow of the color VOILET?
how to find the resistance and gap volatage of the diode??
Draw the circuit of clapp oscillator?
what is the sludge current
at work we have a 3 phase motor but on testing one phase isnt getting a reading. it runs 24 hours a day all week. stops and starts well no noise or heating. the phase isnt down to earth.is it just a bad meter reading or not? phases one and three came up with a resistance reading of 0.4 but phase 2 couldnt get anything shows up as open circuit.
What's the difference between non break power supply and non break non short break power supply
in basic 2 phase will short means tripping the power but spot welding 2 phase shorting but not tripping it will welded why.....(Q)
What is the distance between each insulator in 33kv transformer and how can it calculate
advantages & disadvantages of Lagging and leading power factor .