Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

1KVA transformer of different frequencies of
50hz,100hz,500hz&1000hz. which one of these transformer has
big size? Give reason

Answer Posted / mohd shahid

bhai kishore see here we r talking about same KVA rating
not same KV rating.
here you r equting the KV rating(ie by equating the induced
emfs)
there is a diff between kv and kva hence kindly refer again
to your solution which acco. to me is not correct

Is This Answer Correct ?    8 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the instrument to check the rotating diode fuse of alternator in running conditions?

2426


If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.

1842


What is value of earth resistance required for substation and equipment earthing and what are the reference guidelines

1726


what is deffrence between squirral cage and wound rotor in IM?

1916


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

2094


What is the difference between isolators and electrical circuit breakers?

1096


whats the existence of reactive power and when it arises?

2082


What is minimum phase system?

1092


How many double suspension hardware fittings are required on a double circuit transmission tower?

2041


what is the control circuit for operating the clean room air shower

2216


if any body have question paper of railway (section engineering),then plz send me .i will thank of him/her.

1959


Define the three phase formula fuse.

1816


What is the comparison of PILC and XLPE cable

2043


EXPLAIN THE TRANSFORMER MAINTENANCE?

2208


what kind of technical test that i need to learn because i have an interview tomorrow.. please someone help me..

1965