Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how and where megger works?

Answer Posted / k.babu

Megger inbuilted inside a dynomo which is used to energise
the system. Which is used to find the Earth Resistance

Is This Answer Correct ?    42 Yes 47 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

11 kg trivevter meter has rating of -/5amps. And pt ratio11000/110v and is connected with 11kv ct/pt unit of cr ratio 75/5amps. And pt ratio of 11000/110v while checking accuracy of meter with HT Accuchek meter what value of PT ratio and CT ratio to be filled in Accuchek meter

1932


What is the accepted limit to increase the choosen transformer capacity over the load and why ?

3590


why the colour of insultor stack , petticoat is brown. Is it has some technical reason.

2029


What does the letter CTNM in negative phase sequence relay means?

1824


i want to learn control schedule for 11kv panel? can any one send the detailed control schedule?

2435


how to calculate the mesh earth network resistance in such substation, is there any recommended resistance values with references , thanks!

2343


how to CHECK CT AND PT AT THE FAULT OCCUR IN GENERATOR RELAY PANEL .

2286


What is power relay?

1248


which is the best institute for PLC,SCADA,DCS in hyderabad

2364


1.What is the range of stator resistance of 3-phase induction motor? 2.Two electrically operated vibro motors are foxed in parallel direction in vibrating feeders. what is the direction of both vibro motors?

1897


WHY CBCT USE ONLY IN Y PHASE NOT OTHER PHASES

2121


I WANT BHEL PREVIOUS QUESTION

2366


If the feeder rating is 7.5 kw or 10 HP star-delta feeder, MCCB is taken as 63 a, contactors-32 a, how much will be the OLR rating or which range OLR should be considered when we concern about type-2 coordination?

2316


How shall i select the value of capacitor or inductor in a system?

1906


why voltage form factor of PT are increase , when it is ecpected heigher spikes in system. how it is calculated.

2148