Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Do you have any P.L.C in your organization?

Answer Posted / shivendu

ya i m having plc's in my organization..the plc's is of
Siemens and Honeywell.the Siemens plc's is s-7 300 and
Honeywell plc's is Honeywell loader 620-60

Is This Answer Correct ?    4 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Can any one provide the inspection procedure of MIMIC for VFD panel? Details: If someone wants to have a mimic in the VFD panel what are inputs considered for the mimic(like on,off,trip) whether we are able to add speed variation in the mimic(if so how can we get) and what are the parameters to be checked in the MIMIC during inspection?

2153


What should be the magnetic balance test values for a 3 phase delta/star connected single primary dual secondary winding transformer (90 MVA / 2 X 45 MVA TRANSFORMER)

1850


What happen when change order of CT in GIS feeder?

1599


When a square wave is applied to primary of a transformer then what will be output wave form of secondary ?

2028


DIFFERENCE BETWEEN NORMAL TRAFO AND THRISTER TRAFO?

2559


I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?

1689


How to Calculate KA Rating of Main LT Panel

1694


what id a dry type transformers and its function ?

1715


How to calculate loses in transformer of 160 KVA ?

1612


can we synchronize star system generators with delta system transmission line ? and how ?

2778


how to select size of hardware for linking aluminium busbar is it depend on area of busbar or current flowing through bus bar

1966


why sielent pole is used only in hydro generators and not in turbo generators

4118


If breaker is undefined position, first step to do.

2211


what is the eight bit unit?

2385


I WANT BHEL PREVIOUS QUESTION

2290