Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is difinition of HIGH RESISTANCE FAULT and LOW
RESISTANCE FAULT?

Answer Posted / bryan

A high resistance fault is a fault that causes an over
current in the system but would not cause excessive heating
unless no action is taken for an extended period. A Low
resistance fault occurs and cause an output under voltage
situation and can lead to damage of the system if immediate
action is not taken to cut off the power stream.

Is This Answer Correct ?    25 Yes 17 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

sourse is 66 KV / 350 MVA, transfarmer is 1000 KVA 6.6 / 0.415 kv, iF fault is 28.75 MVA on 0.415 KV Bus then calculat the Transfarmer Impidance

2149


what are factors to be consider in electrical installation like load factor,diversity factor .....

1861


How to Calculate The Neutral Earth flat design calculation for the Synchronised generator (Gen 1-650Kva, Gen 2-725Kva

1726


is this the formula of building wiring to get the main breaker.Watts/volts*.8%+higher motor*(25%)=ampere. yes or no or send the correct formula for building wiring.

1762


In a power conditoining unit (inverter) of a solar plant when we measure the d.c. current fed by different strings of solar plates to inverter, the current in the negative wire is less almost by 1 ampere to the current in its positive wire say current in positive wire 5 A , then current in negative wire of the same string is 4 A. Since the current entering should be equal to current leaving then why the current is noticably less in negative wire.

1656


For a 6.6kV Motor it is recommended to do megger test with 500 V d.c and not more than 5kV d.c but the Hi voltage withstand test should be performed by 12kV AC. Why the dc voltage test should be limited but AC voltage withstand test could be with such a high voltage?

2382


what is the main function of capacitors in mccs.

1782


what is mean by ideal infinite bus? why it is required to consider in fault short circuit calculations?

2753


What is meant by vector group

2628


Why the efficiency of generator is more than motor in swinburne's test

2072


how much cable size required for 70 kilowatt load.

1741


I have motor 1500 HP and , 4160 V , 60 HZ , then i need the rating of transformer which can feed that motor ??

2006


how to electrically make connection to ferroli GN2N?

1998


Which of the following alternatives will be cheaper (1) A 100 h.p AC, 3-phase motor (2) Four motors of 25 h.p each (3) Five motors of 20 h.p each (4) 10 motors of 10 h.p each explain

3098


what is basic difference betmeen normal & flame proof motor??

2259