Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

can any one tell me the formula for calculating the power
and unit consumpetion

Answer Posted / vinothbabu.k

P=(1.732*VOLTAGE*AMPS)/1000,
FOR UNIT CONSUPTION:

KWATTS*HOURS=UNIT-ITS FOR INDUCTIVE LOAD,
FOR RESISTIVE LOAD THE ABOVE IS CORRECT,LAMP HEATER IS
RESISTIVE LOAD,
IT DEPANDS ON TYPE OF LOAD.
AND FOR CAPACITIVE & INDUCTIVE LOAD NO OF WORKING HOURS
WILL BE VARRY,FOR EXAMPLE TAKE FRIDGE WAS WORKING FOR 2
HOUR IT TAKE 750W MEANS WE SHOULD NOT
CALCULATE .750*2=1.5KWHR/UNIT,FRIDGE IS A CAPACITIVE LOAD
IT WILL ON OPPROXIMATELY 35 MIN FOR EVERY PER HOUR SO WE
SHOULT TAKE FOR 2 HRS IT WILL ON 1.05HRS FOR 2 HRS,
SO 750*1.05=0.787 UNIT

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is gridrotor resistance starter

1872


What is the operating principle of turbo-generator.

2341


Damping resistor provided in open delta (tartiary) winding of a measuring PT at the incoming of a MV inverter drive panel is getting heated up. Can any body explain the reasons and suggest the remedy?

3038


what is the purpose of slope in the differential relay?why we are using two slope?but in busbar differential we are using only one slope.why?

2909


Please elaborate th´evenin’s theorem?

1143


Hi everyone. Some Generators uses 3-Pole breakers with extra contactors for Neutral. Some uses 4-Pole. Why so? What is the idea behind this? Thanks in advance for the solution. Kr.

2072


EXPLAIN THE TRANSFORMER MAINTENANCE?

2269


How to calculate ant test the burden of Current transformer

2450


What happens if we give the supply to the rotor of induction motor and make its terminal shorted?

4066


What is meant by reset level of the relay?

1210


L.A. (Lightening Arrester) is located at a place from where transmission line enters the transmitting substation. So L.A. (Lightening Arrester) is the first equipments which has to encounter with lightening, high voltage surges and switching surges. It has to absorb energy of lightening, high voltage surges, and switching surges. L.A. (Lightening Arrester) is made up of layers of semiconductors. If these layers can not tolerate energy released by lightening, high voltage surges, and switching surges the L.A. (Lightening Arrester) blasts.

1100


what is breathing?

1813


What is the formula to calculate the rating of power cable for three phase current.

2133


what is the excess air in furnace

2041


Explain the function and difference of Restricted earth fault, simple earth fault and sensitive earth fault with connection diagram.

2655