Do you know how to joint the H.T and L.T Cables?
Answer Posted / vinothbhabu
hello dear,jointing the cable not by using transformer or
by fevicol,and its not a simple like paper r wood jointing
by fevicol..
by using the heat strinkable method cable jointing will be
done,the heat strinking method gives high insulation to the
cable at jointing end,it can be used for jointing ht panel
board at the termination end,the kit used for the heat
strinkable is heavely insulation material,the joint will be
done by heating material...
for jointing the LT to LT cable above 6
sqmm,10,16,35,50,70,90,120,150,185,240,300,400,sqmm cable
by jointing the FERRULE LUG between the cable joint by
using cripping tools and then insulation tape will be
rounded it heavely......
| Is This Answer Correct ? | 114 Yes | 17 No |
Post New Answer View All Answers
Mention the disadvantages of low power factor? How can it be improved?
Explain in brief description about the operation of DG sets.
How seriving & testing of the HT & LT breakers are done. What are the standard Ir values on which we can come to know the test is passed or failed?
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
i installed 100kva ups. what KVA genset they should provid in input side? plz any update formula or ans with reason.
What is s-domain and its significance?
In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes
What will happen if i replace a inductive proximity switch with photo sensor in a machine?
how can we select the type of wire.what factors we have to look on it , do we have some formula to calculate it. please guide me on it
Why space heater is required for each verical bus bar chamber? if one space heater is adequate or not for anti condensation?
what is reverse power relay brief explanation and in b/w where it is connected
what's the simultenous maximum demand (SMD)..what the diffrent MD and SMD?
Why power genaration in India is at 50HZ while America its 60HZ
WHAT IS SITTING AMPS IN OVER-LOAD RELAY FOR 1PH OR 3PH MOTORS?IF ITS NAME PLATE GIVEN MAX AMPS 10AMPS?
what is servo motor and how it works?