Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why we should use delta connection in primary and star
connection in an distribution transformer, which converts
400v a.c. voltage to 33kv.

Answer Posted / engr. abdul barek, electrical

We use in star connection in seconday connection becouse
need neutal point in load sied( some load supply need 3
phase and some need single phase)but it is remember that
only star connection use in distrubution side transformer.

Is This Answer Correct ?    82 Yes 30 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

physical identification of HT & LT panel

1675


how to calculate the fault in substation

2460


explain transformer ct connection?

2063


Why the unit sizes of hydro generating machines are not standardized as in case of thermal powerplants?

1107


Single line diagram for dbb (double bus bar)system.

1946


What are the disadvantages of autotransformer?

1118


can u please mail me the syllabus for GET exam for damodar valley corporation?

2079


What si the d/f b/w KVA & KWH, kvarh & kvar, kwh & kvar phase voltage & line voltage

6167


what is transformor oil gread

2541


why d.c produces corrosion

2037


there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit

1932


How to calculate main incomer rating of APFC Panel ? Let's say i want to find main incomer for 11kV, 1000kVAR Panel.

1954


I want to replace the 3 KW DC motor with AC motor so what should be the rating of AC motor? Details Of DC motor to be changed with AC are - Kw - 3, Vf - 310, If - 0.15, Va - 400, Ia - 13, RPM - 2400

1817


draw singleline diagram of star to delta and dol starters

2257


i have 90kw motor.so i choose connect cable .please what is parameter checked so please give to formula

2213