Why do we buy you?
11kv/433v delta/star distribution transformer primary side full load Ht current is 83.33A in , but input side VCB rating 800A.why?
In apron feeder how TPH is calculated?
a)In a 3-phase 4-wire circuit, a circuit breaker is selected to protect the circuit whose highest fault level is 6.6 MVA. Determine the required minimum breaking capacity in kA. (Note: Covert 3-phase power in terms of kA to find answer.) b)Using the below, determine the required minimum making capacity in kA as a “peak value”. Rate breaking capacity (Icn) ka: Icn<= 1.5 Factor = 1.41 1.5
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
Gidc technical que paper
Positive and Negative test cases for the speedometer?(minimum 5 each)
Build with fixes has been deployed on QA environment if asked by your manager to reproduce how can you reproduce the issues? (by using the previous build) Can you access the previous build? If so ,what are the tools or how can you access?
How to define Kirchhoff current law and voltage law along with simply examples.
could anyone tell me how we can copy the mass roles from sap_all profiles???????
Stringer How many cm goes to landind
Hi, I would like to check if my understanding is correct I have a negative amount for provision of income tax in my balance sheet from my previous financial year.What are the accounting treatments for income tax paid and then refunded to you for the current year? Is this correct? For payment Dr provision of income tax cr bank For tax refund Cr provision of income tax Dr bank Do I need to input anything in income tax expense acct?
Rate analysis for construction of a solid block masonary of size 400x200x200 in C.M.1:5 in superstructure .Compressive strength 5.00 N/Sq.mm Confirming to IS: 12894:1990, with necessary scaffolding, raking of joints and pointing the same. I require rate per Cum.
due date for issue of C form, if c form is not issue what will be the consequences
What was use of tally erp 9? Types of vat?