Answer / guest

Cause: An improper command was sent to the Connection
Manager or it is not responding. Not normally visible to the
user.

Action: Verify that the correct addresses are listed in the
TNSNAMES.ORA, TNSNET.ORA, and TNSNAV.ORA configuration
files. Also check that the Connection Manager is running by
using the STATUS command of the Interchange Control Utility.
If the error persists, contact Oracle Customer Support.