Where the excitation is given either stator or rotor in
actually in power plants?
Answer Posted / paul
In thermal power plants the excitation is given in the
Rotor, (since the speed is high) and in the hydro Electric
power plants the excitation is given in the stator. (speed
is low)
| Is This Answer Correct ? | 0 Yes | 10 No |
Post New Answer View All Answers
State thevenin’s theorem?
If any cable burnt how can we identify it burnt by high current of high voltage?
how do you choose the cable size as per amps rating & the voltage drop for the same.
what questions are asked in the interview for the post of an electrical maintenance engineer in FMCG companies?
What is the method of estamating of cable, CB,MCB ?
why and how current drawn by battery charger depends upon the altitude where it is located?
WHERE CAN I GET THE PREVIOUS QUESTION PAPERS OF Govt Polytechnic in deee 2nd year papers
what is the diff. between x'mer , isolation x'mer & ultra-isolation x'mer ?????????????
what is transient enclosure vltage , very fast transients, very fast transient over voltages
what will happen if multimeter(selector switch at DC voltage) and terminal at current is connected to DC supply?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
Why should be the frequency 50 hz 60hz only why not others like 45, 95 56 or anything , why should we maintain the frequency constant if so why it is only 50 hz 60hz?
What is the difference between PS & metering CT (5p20,0.5 etc.)? Why in PS class CT only Vk is given ? Is PS class CT is more accurate than metering CT?
How to calculate VCB rating for 33KV ,25 MW Power line?
how can we find thae value of capacitor for single phase motor. what is difference between starting capacitor and running capacitor.