What is the reason for low voltage in houses?
Answer Posted / murali
* We using many indutive loads(FANS,ANY MOTORS)
so powerfactor is below 0.4 (leading current in voltage)
so produce voltage drops
* Using capacitors in parallel to the loads
improve the powerfactor
* loads are properly divided reduce the voltage drops
| Is This Answer Correct ? | 35 Yes | 16 No |
Post New Answer View All Answers
If a surge divertor is required to be protected by 32 amp C Curve Circuit breaker does this limit the amount of protection from surges that you will acheive
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
what are the preventive maintanance actions taken for air circuit breaker? please answer me
why in the three pin plug all 3 pins are cutted ?
Which type of a.c motor is used in the fan (ceiling fan, exhaust fan, pedestal fan, bracket fan etc) which are find in the houses ?
I WANT BHEL PREVIOUS QUESTION
Is there any Electrical supervisor license which gives permit to work whole India rather than individual state??
what is the current density of copper & alluminium.
What is CCM in Electrical ? where can we use this material?
how to find three phase complex power in per unit and MVA?
in Contactor opearation Why there is a difference in the values of the operate and release voltage in case AC supply
comparision between ACB and VCB
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
what is class of SPD and dittels of all class ?
at what rate the micro controller increment its timer....is it 1micro seconds or 1/(12*10^6) seconds